The following test sequence will verify that your pole display is working properly.  Before you start this procedure, you must install the pole display correctly as outlined under the INSTALLATION section. The functional test should be done under MSDOS command prompt by booting up the computer in DOS mode, or shell out to DOS prompt (in Window95/98/ME) or COMMAND prompt (in Windows NT/2000/XP).

NOTE:    The actual key entries in the text below are enclosed within quotation marks ( “ ” ). Do not type the quotation marks as part of your entries.

 

This test procedure assumes the pole display is connected to COM1 of the computer. If COM2 is being used, type COM2 where COM1 is specified.

Close all opened application programs that use the same COM port before going into DOS COMMAND prompt.  Enter the following command lines to open the COM port for communication with the pole display:

1.     Type “MODE COM1 96,N,8,1” and press the ENTER key.

2.     Type “TYPE CON>COM1” and press the ENTER key.

 

LDX9000, LDX9300, LDX9400, LDX9500, LDX9900

3.     Type “ABCDEFGH” and press ENTER key. The display will show “ABCDEFGH” on the first line.

4.     To end the test press Ctrl-C (hold down Ctrl and press C).

LDX9200

3.     Type “!#1ABCDEFGH” and press ENTER key. The display will show “ABCDEFGH” on the first line.

4.   To end the test press Ctrl-C (hold down Ctrl and press C).